Thermal/Structural Submeeting - AMS02 TIM AT CERN May 8, 2002 Present: C. Balasubraminian, R. Becker, J. Burger, C. Clark, R. Dasgupta, L. de Franchis, A. Franzoso, C. Gargiulo, R. Harold, J. Krieger, G. Laurenti, K. Lübelsmeyer, T. Martin, M. Molina, M. Pohl, D. Rapin, D. Read, G. Sardo, R. Schlitt, R. Siedling, C. Tutt, B. Verlaat List of Action Items: 1. OHB to verify the zenith radiator and upper plate to be correctly modelled OHB 17th May 2. ISATECH to provide OHB mechanical data for evaluation of the TRD I/F conductance ISATECH/RWTH 17th May 3. OHB to provide CGS with TRD to USS I/F conductance OHB 20th May 4. CGS to provide significant temperatures of the TRD on the sidewalls for the two available cases without changing the model CGS 24th model 5. Check significant temperatures of the TRD on the sidewalls for the two available cases with updated model and provide them to OHB / AACHEN CGS 24th may 6. Provide OHB system I/F data relevant to AMS02 model including TRD model for the two available cases CGS 24th May 7. Check TRD enclosure bottom temperature value CGS 31 May 8. OHB to apply new TOF power within the enclosure (3.2 W instead of 14.4 W) OHB 6th June 9. Cables are not in the model: Aachen to provide approximate routing, exposed surfaces of cables and gas tubing 10. Thermal worst hot case (thermostat failure case) will be analyzed and data provided to OHB for Heat pipes MDP calculation CGS 15th June 11. OHB to assess MDP for heat pipes OHB 30th June 12. OHB/CGS to invesigate responsibility for heaters for cryocoolers with GSFC OHB/CGS 2nd June 13. LMSO (Dasgupta) to provide strength properties of 6061 after brazing at 210°C LMSO 24th May 14. OHB to assess the feasibility of 3 mm OD tube for zenith radiator with the residual strength OHB 31st May 15. OHB to check white paint availability for space application, to be submitted to LMSO for approval OHB 15th June 16. CGS to provide updated AMS02 thermal model and results CGS 7th June 17 LMSO to run the new model and compare results LMSO 14th June 18 LMSO will calculate new thermal induced deflections LMSO 21th June ***************** Structural meeting 1. CGS delivered 3 Structural analysis reports (TOF Upper, RICH, Crates system and radiator), based on a combination of SVP inertial loads combined with acoustic (for the radiators only) and boundary displacements provided by LMSO 2. LMSO to include TRD FEM model in the AMS02 model LMSO 24th May 3. CGS/OHB to proceed with structural design for the tracker radiator brackets, including condensers mass, up to a bracket conceptual design CGS/OHB 30th June 4. LMSO to select an approach to provide design loads to the subdetectors/subsystems LMSO 24 May 5. LMSO to provide dimensioning data for subdetectors/subsystem LMSO 24 May